Latest EAF Off-Gas Results Using Deep View Infra-Red Technology
The infrared exhaust gas measurement system for electric arc furnaces and similar ovens has been successfully established on the market for 2.5 years. Initial long-term results are now available, demonstrating the system’s reliability and effectiveness. The new function tested at the ESF steel plant in Riesa, Germany, is the ability to measure CO content of the furnace gas under the roof of the furnace with a sensor installation on the D2 duct. By this the CO concentration in the offgas duct as well as under the roof can be measured simultaneously with only one sensor location on the offgas duct.
Authors:
Hans Georg Conrads | PROMECON process measurement control GmbH
Session Chairs:
Antony Faulds | U. S. Steel - Fairfield Works
Bob LaRoy | Steel Dynamics Inc. - Flat Roll Group - Butler
Latest EAF Off-Gas Results Using Deep View Infra-Red Technology
Category
Presentation Only
Description
Session: Electric Steelmaking: Operations II
Track: Electric Steelmaking
Date: 5/5/2025
Session Time: 2:00 PM to 5:00 PM
Presentation Time: 04:00 PM to 04:30 PM
Track: Electric Steelmaking
Date: 5/5/2025
Session Time: 2:00 PM to 5:00 PM
Presentation Time: 04:00 PM to 04:30 PM